Kit isolante para flanges.
|
TEST METHOD |
FEATURES |
Mylar® (1) | Nomex® (1) | G10 (FR4)(2) | G11 (FR5)(2) |
|---|---|---|---|---|---|
| D149 | Dielectric Strength KV/mm Short Time | 15,8 | 18,0 | -29,5÷31,50 | 21,5 |
| D695 | Compressive Strength (MPa) | - | - | 448,0 | 434,0 |
| D638 | Tensile Strength (MPa) | 69,0 | 620,0 | 344,0 | 290,0 |
| D570 | Water Adsorption (%) | 0,8 | 7,0 | 0,1 | 0,1 |
| -- | Temperature - Operating °C | -50÷150 | -50÷230 | -150÷150 | -75÷200 |
Note (1): Material available only for sleeves.
Note (2): Material available for retainer, sleeve, and washer.
|
Gasket Pressure range |
|
Sealing Element - Temperature range |
||
|---|---|---|---|---|
| ASME Gasket Pressure Range | 150÷1500 lbs | PTFE | -200°C÷250°C | |
| API Gasket Pressure Range | 2000÷5000 psi | NBR | -40°C÷120°C | |
| PN Gasket Pressure Range | PN6÷PN250 | FKM | -29°C÷200°C | |
* The maximum operating temperature of the kit is the lowest among its individual components.
* Customized kits are available with tailored thickness and component materials.